Stator Slot RTD's are used to monitor winding temperature of large Motor and Generator available both in Simplex and Duplex type.
FEATURE
Bidirectional winding to Prevents electrical noise to appear into the measurement
Lead wire pull test , Tap test & Bend Test carried out on 100 % sensors
Vibration and Shock proof design
Thermal aging test for 24 Hrs. is carried out on 100 % sensors
Dielectric Strength of upto 5.0 kV is available on request.
GENERAL SPECIFICATION
|
TYPE |
PT 100 - Wire Wound Type / Thin Film Type |
|
ELEMENT |
SIMPLEX/ DUPLEX |
|
TEMPERATURE CLASS |
Class F(Temperature limit:155°C) or |
|
CALIBRATION STANDARD |
IEC 60751 α= 0.003850 , 0.003920 |
|
ACCURACY CLASS |
A / B / C |
|
SENSING CURRING |
10 mA (Max.) |
|
DIELECTRIC STRENGTH |
1.0 kV to 2.0 kV for 60 Sec. 5.0 kV for 1.0 Min. on request. |
|
NUMBERS OF WIRE |
2 Wire / 3 Wire / 4 Wire |
|
LEAD WIRE |
PTFE insulated Silver Plated Copper Wire. |